Incident review / Manned Spacecraft Center, Houston
Houston, we've had a post-mortem.
55:55:42LovellHouston, we've had a problem.
- Incident
- AS-508
- Detected
- 55:54:53 MET
- Severity
- Crew safety
- Status
- Resolved
- Format
- Blameless
01 / Summary
One tank failed. Three crew came home.
- What happened
- At 55:54:53, oxygen tank 2 in the service module failed and took tank 1 down with it.
- Impact
- Lunar landing cancelled. Three crew lived four days in a lander built for two people and two days.
- Root cause
- Heater switches rated for 28 V met a 65 V ground supply, welded shut, and cooked the wiring.
- Resolution
- Lifeboat ops in the lunar module. Splashdown at 142:54:41, April 17, 1970.
Apollo 13 Review BoardTL;DR
02 / Impact
We lost the landing. We kept the crew.
- Lunar landing
- CancelledFra Mauro, not visited
- Distance at failure
- 205,000 miFrom Earth, outbound
- Lifeboat load
- 3 crew, 4 daysIn a lander rated for 2 and 2
- Time to resolve
- 87 hours55:55 to 142:54 MET
3 /3
03 / Timeline
143 hours, logged to the second. Scrub any of them.
MET142:54:41
Fri Apr 17 1970, 1:07 pm EST
Splashdown142:54:41
Mid-Pacific, 3.5 nautical miles from USS Iwo Jima.
Nominal Incident Recovery
04 / Detection
We detected the failure in 27 seconds. The odd reading came nine hours sooner.
O2 tank 2 quantitySchematic, MET hours
40h46h52h58h
- Time to detect
- 27 sBang to first crew report
- Time to diagnose
- 1.5 hTank 1 leak judged unstoppable
- Time to mitigate
- 2h 45mLifeboat live by 58:40
- Anomaly age
- 9h 15mGauge fault, unexplained
05 / Response
The lander became the lifeboat.
- 58:40
- Aquarius powered up as the lifeboat
- 20%
- Lander power, cut to a fifth of normal
- 4
- Course corrections on a lander engine
05 / Response, continued
Spare filters: square. Sockets: round.
0.1 mm Hg
Fix installed at 93 h
LM cabin CO2, mm HgCurve illustrative
60h71h82h93h104h
06 / Root cause
Five whys, from the bang back to a 1965 spec change.
- Why 1
Why did tank 2 fail at 55:54?
The crew stirred it. Damaged fan wiring shorted, and its Teflon insulation ignited in pure oxygen.
1970 - Why 2
Why was the wiring damaged?
Before launch, the tank heaters ran for 8 hours straight. Parts of the heater tube reached about 1,000 F.
Mar 1970 - Why 3
Why did the heaters run for 8 hours?
Tank 2 would not drain after the countdown test, so the team boiled the oxygen off. Its fill tube was likely knocked loose when the tank was jarred in 1968.
Oct 1968 - Why 4
Why didn't the thermostats cut the heat?
They were rated for the spacecraft's 28 V. The ground supply was 65 V. The first time they opened, they welded shut.
Mar 1970 - Why 5
Why were 28 V switches on a 65 V tank?
A 1965 spec change moved the heaters to 65 V. The switch spec never followed, and no test cycled the switches under load.
1965
Root cause A spec changed and a part didn't. The board: a serious oversight in which all parties shared.
07 / Retro
Some of it was skill, some of it was process, and some of it was luck.
Went well
- Lifeboat checklists already existed. Mission Control stretched them to three crew and four days.
- The ground team built, tested and read up a CO2 fix before the limit hit.
- Swigert joined the crew two days before launch and flew it like he had trained for months. He had.
Went wrong
- The tank 2 gauge failed at 46:40. Nobody had to explain it.
- The heater temperature sensor read to 85 F. The heater reached about 1,000 F.
- Prelaunch reviewers never saw an 8-hour heater run as a risk.
Got lucky
- It happened outbound, with the lunar module attached and fully stocked.
- Tank 2 was hazardous from the pad onward. It held for 56 hours.
- When Aquarius was let go, it had about 4.5 hours of power left.
08 / Action items
Nine recommendations. Every one has an owner.
ShippedApollo 14 waited three months for these
09 / Follow-ups
Status: resolved. Crew: home.
- Jun 15, 1970 Review published Cortright hands the report to Administrator Paine.
- Jun 16, 1970 Briefed to Congress House Committee on Science and Astronautics.
- Jan 31, 1971 Apollo 14 flies Third oxygen tank, new thermostats, no stirring fans.